EVI low temperature mono-bloc air source heat pump installation

Product Details:

Place of Origin:Guangzhou/China
Brand Name:HISEER
Model Number:AW10/L-DNNNE
Certification:CE / EN14511

Payment & Shipping Terms:

Minimum Order Quantity:2 pieces
Packaging Details:plywood
Delivery Time:10-15 days after receiving TT payment
Payment Terms:TT payment
Supply Ability:100 pieces / per day
Detailed Product Description

EVI low temperature mono-bloc air source heat pump installation

When the ambient temperature drops to below zero degree in winter, the normal air source heat pump can not run stably caused by the system low evaporated temperature, small gas absorption , small system gas flow and unstable superheat degree, etc . So that the air source heat pump’s heating output is low , the system runs unstably , even worse to cause the compressor damaged. Normal air source heat pump can not meet the heating requirement in the cold area in winter. So, the market for the heat pumps that can work under low ambient temp. is promising.

 

Injection mono-bloc air source heat pump AW10/L-DNNNE, 380-415V/3/50Hz, R410a, approved by TUV china branch, easy installation unit, adopt the following world famous parts:

*Hitachi EVI compressor

*SWEP or GEA plate type heat exchanger

*Schneider A/C contactor

*Saginomiya low pressure switch

*Carle pressure sensor

*Honeywell R410a refrigeration

 

HISEER low temperature air source heat pump AW10/L-DNNNE, adopt Hitachi EVI compressor, can be used at -20 degree outside temperature. The injection new technology make it possible that, even at -15 degree, the efficiency of the heat pump can reach 1.9. This is the ideal product to be used at the rather cold winter area.

 

AW10/L-DNNNE

LOW TEMPERATURE AIR TO WATER HEAT PUMP

AW10/L-DNNNE

Heat output/Power consumption at 7/35℃

kW

11.40/2.70

Heat output/Power consumption at 7/45℃

kW

12.10/3.41

Heat output/Power consumption at 7/55℃

kW

12.18/4.19

Heat output/Power consumption at 2/35℃

kW

10.30/2.70

Heat output/Power consumption at 2/45℃

kW

11.63/3.37

Heat output/Power consumption at -7/35℃

kW

9.78/3.04

Heat output/Power consumption at -7/45℃

kW

9.66/3.58

Heat output/Power consumption at -10/35℃

kW

8.75/3.04

Heat output/Power consumption at -10/45℃

kW

8.57/3.62

Heat output/Power consumption at -15/35℃

kW

7.82/3.09

Heat output/Power consumption at -15/45℃

kW

7.73/3.62

Starting current 

A

53

Power

 

380-415V/3PH/50Hz

Compressor

 

HITACHI scroll

Condenser

 

Brazed plate heat exchanger

Nominal flow heating medium

l/s

0.55

Internal pressure drop at nominal flow

kPa

16

Air flow

m3/h

5000

Nominal output fan

W

300

Max outgoing heating medium temperature

55

Dimensions(HxWxD)

mm

1075X1105X505

Pipe connector

 

DN32

Weight

kg

185

The above data is tested by EN14511

 